• DocumentCode
    3081918
  • Title

    A two-stage approach to positioning and identification of tracheal intubation using LED-based lightwand and acoustic models

  • Author

    Chen, Wei-Hao ; Su, Hao-Po ; Chiu, Yu-Hsien ; Tseng, Chia-Chi ; Chung, Kao-Chi

  • Author_Institution
    Institute of Biomedical Engineering, National Cheng Kung University, No. 1, Ta-Hsueh Road, Tainan, 701, Taiwan, Republic of China
  • fYear
    2008
  • fDate
    20-25 Aug. 2008
  • Firstpage
    4883
  • Lastpage
    4886
  • Abstract
    This paper proposes a two-stage approach to positioning and identifying tracheal intubations by computer-assisted diagnosis system. First, an innovated LED-based lightwand is developed for positioning the opening of the trachea and inserting the endotracheal tube rapidly. The proposed LED-based lightwand instrument significantly reduces the effects of temperature reaction without changing transillumination through the tissue. After intubation, breath sound analysis instrumentation is developed and assists for identifying the accurate tube position. To overcome the fast and overstepped variations of amplitude, a high sensitivity omni dimensional microphone and an automatic gain control device with linear phase property are calibrated and conducted into experiments of operating intubations. User-friendly interface software is also developed to analyze and transcribe the physiological characteristics of the collected breath sound corpus. Several subjective and objective experiments are performed to examine the practicability of the proposed approach and systems. The preliminary results show that the proposed LED-based lightwand instrument outperformed in the tip temperature without the influence on transillumination. The proposed parameters of average vibration parameter variance (AVPV) and frequency-domain energy variance (FEV) revealed the potential for distinguishing between the tracheal and esophageal intubations.
  • Keywords
    Biomedical engineering; Cardiac arrest; Computer aided diagnosis; Error analysis; Esophagus; Gain control; Instruments; Medical diagnostic imaging; Microphones; Temperature sensors; Tracheal intubation; acoustic models; esophageal intubation; lightwand; Acoustics; Animals; Diagnosis, Computer-Assisted; Equipment Design; Equipment Failure Analysis; Intubation, Intratracheal; Lighting; Reproducibility of Results; Semiconductors; Sensitivity and Specificity; Swine;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2008. EMBS 2008. 30th Annual International Conference of the IEEE
  • Conference_Location
    Vancouver, BC
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-1814-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2008.4650308
  • Filename
    4650308