• DocumentCode
    3089148
  • Title

    Improvement of dynamic performance for the direct torque controlled induction motor system fed by a three-level inverter

  • Author

    Li, Hongmei ; Wang, Jian ; Wang, Xiaochen

  • Author_Institution
    Dept. of Electr. Eng., Hefei Univ. of Technol., Hefei, China
  • fYear
    2010
  • fDate
    15-17 June 2010
  • Firstpage
    1335
  • Lastpage
    1339
  • Abstract
    Higher dv/dt and neutral point voltage floating often occur at the common three-level inverter, therefore, the modified modulate strategy is first studied for an induction motor system (IM) fed by a three-level inverter to implement direct torque control (DTC), and then the SIMULINK model is set up for the direct torque controlled induction motor system fed by the modified three-level inverter´s modulate strategy. Simulation results show that the modified modulate strategy can not only overcome the shortage of neutral point voltage floating and higher dv/dt in the common three-level inverter, but also reduce the torque ripple, therefore, improve the dynamic performance of a direct torque controlled IM system markedly.
  • Keywords
    induction motors; invertors; torque control; SIMULINK model; direct torque controlled induction motor system; modified three-level inverter modulate strategy; neutral point voltage floating; Control system synthesis; Control systems; DC motors; Electronic mail; Induction motors; Inverters; Sampling methods; Switches; Torque control; Voltage control; DTC; Dynamic performance; IM; Modified modulate strategy; The three-level inverter;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics and Applications (ICIEA), 2010 the 5th IEEE Conference on
  • Conference_Location
    Taichung
  • Print_ISBN
    978-1-4244-5045-9
  • Electronic_ISBN
    978-1-4244-5046-6
  • Type

    conf

  • DOI
    10.1109/ICIEA.2010.5514917
  • Filename
    5514917