Abstract :
This paper presents some guidelines for verifying the accuracy of a frequency dependent transmission line model in a time domain simulation program, such as EMTP. The guidelines are described for our quasi-mode transmission line model, which is applied to an actual 440 kV single three-phase transmission line model, using ATP
Keywords :
power overhead lines; power system transients; time-domain analysis; transmission line theory; 440 kV; ATP; EMTP; frequency dependent transmission line model; overhead lines; quasi-mode transmission line model; three-phase transmission line model; time domain simulation program; transient behaviour; transmission line modeling; EMTP; Eigenvalues and eigenfunctions; Electromagnetic modeling; Frequency dependence; Frequency domain analysis; Guidelines; IEEE members; Power system transients; Testing; Transmission lines;