DocumentCode
3090801
Title
Significant reliability improvement of NMR systems
Author
Amiri, Moslem ; Prenosil, Vaclav
Author_Institution
Fac. of Inf., Masaryk Univ., Brno, Czech Republic
fYear
2015
fDate
19-21 May 2015
Firstpage
1
Lastpage
4
Abstract
Majority voted redundancy is increasingly implemented in fault-tolerant design today. In this technique, a voter receives parallel bits from an odd number of digital components and votes for the majority. Reliability improvement is the main focus of every fault tolerant system design. In this paper, we first present a viable alternative to the voting redundancy concept in order to significantly increase the reliability of conventional voting systems for five parallel components or higher. Then, an implementation of this novel concept is described.
Keywords
circuit reliability; fault tolerant computing; logic design; redundancy; N-modular redundancy; NMR systems; fault tolerant system design; majority voted redundancy; reliability improvement; voting redundancy concept; Digital circuits; Fault tolerant systems; Integrated circuit reliability; Nuclear magnetic resonance; Redundancy; Reliability engineering; Reliability; fault tolerance; redundancy;
fLanguage
English
Publisher
ieee
Conference_Titel
Military Technologies (ICMT), 2015 International Conference on
Conference_Location
Brno
Print_ISBN
978-8-0723-1976-3
Type
conf
DOI
10.1109/MILTECHS.2015.7153717
Filename
7153717
Link To Document