Abstract :
Focused ultrasound (FUS) in the presence of systemically administered microbubbles has been shown to locally, transiently and reversibly increase the permeability of the blood-brain barrier (BBB), thus allowing targeted delivery of therapeutic agents in the brain for the treatment of central nervous system diseases. Currently, microbubbles are the only agents that have been used to facilitate the FUS-induced BBB opening. However, they are constrained within the intravascular space due to their micron-size diameters, limiting the delivery effect at or near the microvessels. In the present study, acoustically-activated nanodroplets were used as a new class of contrast agents to mediate FUS-induced BBB opening in order to study the feasibility of utilizing these nanoscale phase-shift particles for targeted drug delivery in the brain. Significant dextran delivery was achieved in the mouse hippocampus using nanodroplets at clinically relevant pressures. Conventional microbubbles with the same lipid shell composition and perfluorobutane core as the nanodroplets were also used to compare the efficiency of FUS-induced dextran delivery. It was found that nanodroplets had a higher BBB opening pressure threshold but a lower stable cavitation threshold than microbubbles, indicating that contrast agent-dependent acoustic emission monitoring should be carried out. More homogeneous dextran delivery within the targeted hippocampus was achieved using nanodroplets without inducing inertial cavitation or compromising safety. Our results offered a new means of developing the FU-Sinduced BBB opening technology for potential extravascular targeted drug delivery in the brain, extending the potential drug delivery region beyond the cerebral vasculature.
Keywords :
biomedical ultrasonics; blood; brain; drug delivery systems; nanomedicine; nanoparticles; neurophysiology; organic compounds; patient monitoring; permeability; FITS-induced BBB opening; FITS-induced BBB opening technology; FITS-induced dextran delivery; acoustic-activated nanodroplets; blood-brain barrier permeability; central nervous system disease treatment; cerebral vasculature; contrast agent-dependent acoustic emission monitoring; contrast agents; dextran delivery; extravascular targeted drug delivery; focus ultrasound-induced blood-brain barrier opening; high BBB opening pressure threshold; homogeneous dextran delivery; inertial cavitation; intravascular space; lipid shell composition; low stable cavitation threshold; micron-size diameters; microvessels; mouse hippocampus; nanoscale phase-shift particles; perfluorobutane core; targeted drug delivery; Acoustic emission; Fluorescence; Hippocampus; Mice; Targeted drug delivery; Ultrasonic imaging; blood-brain barrier (BBB) opening; drug delivery; microbubbles; nanodroplets; nanomedicine;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium (IUS), 2013 IEEE International
Conference_Location :
Prague
ISSN :
1948-5719
Print_ISBN :
978-1-4673-5684-8
Type :
conf
DOI :
10.1109/ULTSYM.2013.0159
Filename :
6724921
Link To Document :
بازگشت