• DocumentCode
    3094921
  • Title

    Transcranial Doppler ultrasound using adaptive beamforming technique for the suppression of high-intensity interferences

  • Author

    Okumura, Susumu ; Taki, Hirofumi ; Sato, Takao ; Kita, Akira

  • Author_Institution
    Kyoto Univ., Kyoto, Japan
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    1480
  • Lastpage
    1483
  • Abstract
    The control of vasospasm is important in postoperative management after the occurrence of subarachnoid hemorrhage. Transcranial Doppler ultrasound (TCD) is a diagnostic safety test that measures the blood flow in the cranium; however, TCD has low reliability because of the high-intensity interference returned from the cranium. In this study, we employed two techniques to suppress interferences. First, we used a moving target indicator (MTI) filter that suppresses echoes from undesired stationary targets. Second, we applied spatial domain interferometry with the Capon method to the signal after MTI filtering. The desired signal from red blood cells is supposed to have a low correlation with the interferences from undesired stationary targets. We thus averaged the covariance matrix to range direction without averaging sub-matrices in the diagonal direction. In a simulation study, we succeeded in estimating blood flow velocity with an average estimation velocity error of 0.2 m/s, where the desired signal intensity from red blood cells is 60 dB lower than the cranium interference intensity. The center frequency of the pulse is 2.0 MHz and the pulse length is 5 μs. These results indicate the high potential of the proposed method for improving the estimation accuracy of blood flow velocity in the cranium.
  • Keywords
    array signal processing; biomedical ultrasonics; blood flow measurement; cellular biophysics; covariance matrices; filtering theory; medical signal processing; velocity measurement; Capon method; MTI filtering; TCD; adaptive beamforming technique; blood flow velocity estimation; covariance matrix; cranium interference intensity; diagnostic safety test; high-intensity interferences; moving target indicator filter; postoperative management; red blood cells; signal intensity; spatial domain interferometry; subarachnoid hemorrhage; suppress echoes; transcranial Doppler ultrasound; vasospasm; Blood flow; Cranium; Doppler effect; Estimation; Hemorrhaging; Interference; Ultrasonic imaging; Capon method; Transcranial Doppler ultrasound; adaptive beamforming; blood flow velocity estimation; spatial domain interferometry;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2013 IEEE International
  • Conference_Location
    Prague
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-5684-8
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2013.0375
  • Filename
    6724957