• DocumentCode
    3095744
  • Title

    Ultrasound Speckle Image Process Using Wiener Pseudo-inverse Filtering

  • Author

    Juang, Puu-An ; Wu, Ming-Ni

  • Author_Institution
    Nat. Chung-Hsing Univ., Taichung
  • fYear
    2007
  • fDate
    5-8 Nov. 2007
  • Firstpage
    2446
  • Lastpage
    2449
  • Abstract
    We present a basic design and experimental results of a speckle noise reduction method for ultrasound images. Our method utilizes a Wiener filtering algorithm with pseudo-inverse technique. The method is capable of solving the speckle noise problem in ultrasound image by setup a noise function of constant dB. The key idea of the Wiener filtering algorithm is to process the given ultrasound signal by making the filtering less sensitive to slight changes in input conditions. In this paper we investigate the possibility of employing this approach for pre-processing ultrasound image application. We also compare the processed images with the original one. The application of the proposed method for reducing speckle noise is demonstrated by the example.
  • Keywords
    Wiener filters; filtering theory; image denoising; speckle; ultrasonic imaging; Wiener pseudoinverse filtering; filtering algorithm; speckle noise reduction method; ultrasound speckle image process; Biomedical imaging; Distortion; Filtering algorithms; Magnetic resonance imaging; Medical diagnostic imaging; Noise reduction; Speckle; Ultrasonic imaging; Ultrasonic variables measurement; Wiener filter; Pseudo-inverse technique; Speckle noise; Wiener filtering algorithm;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial Electronics Society, 2007. IECON 2007. 33rd Annual Conference of the IEEE
  • Conference_Location
    Taipei
  • ISSN
    1553-572X
  • Print_ISBN
    1-4244-0783-4
  • Type

    conf

  • DOI
    10.1109/IECON.2007.4460013
  • Filename