• DocumentCode
    3095810
  • Title

    Transcranial ultrasound neuromodulation of the contralateral visual field in awake monkey

  • Author

    Deffieux, Thomas ; Younan, Youliana ; Tanter, Mickael ; Aubry, J.-F. ; Wattiez, Nicolas ; Pouget, Pierre

  • Author_Institution
    Inst.-Langevin, ESPCI-ParisTech, Paris, France
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In this work, we investigated the effect of low intensity pulsed focused ultrasound in the brain of two awake Maccaca Mulatta monkeys using the antisaccade (AS) paradigm. The objective of the study was to determine if transcranial ultrasound has an effect on behavioural tasks in awake animal involving a specific brain structure. Two Maccaca Mulatta monkeys (Y and L) were trained to perform antisaccade (AS) movements where they initially have to fix a central stimulus on a screen and then refrain from looking at an appearing peripheral target but instead initiate as soon as possible a saccade towards the opposite direction. In order to investigate the effect of low intensity focused ultrasound, a continuous 100 ms sonication pulse (derated pressure estimated at 0.35 ± 0.05 MPa) was focused at the frontal eye field using a 320 kHz transducer (H115, Sonic Concept, Bothell, WA, USA). Ipsilateral mean AS latencies with ultrasound stimulation were significantly (t-test;monkey Y: p=.0345, monkey L: p= .0311) increased compared to the non-stimulation condition (monkey Y: +14ms; monkey L: +15 ms). The study demonstrates the feasibility of using focused ultrasound to causally modulate behaviour in awake non-human primate brain.
  • Keywords
    behavioural sciences; brain; eye; neurophysiology; ultrasonic therapy; ultrasonic transducers; H115; Ipsilateral mean AS latencies; antisaccade movements; antisaccade paradigm; awake Maccaca Mulatta monkeys; awake animal; awake nonhuman primate brain; behaviour modulation; behavioural task; central stimulus; continuous sonication pulse; contralateral visual field; frequency 320 kHz; frontal eye field; low intensity pulsed focused ultrasound; nonstimulation condition; peripheral target; specific brain structure; time 100 ms; transcranial ultrasound neuromodulation; transducer; ultrasound stimulation; Acoustics; Animals; Magnetic resonance imaging; Neurosurgery; Transducers; Ultrasonic imaging; Visualization; brain; neuromodulation; neurostimulation; non human primates; visual task;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2013 IEEE International
  • Conference_Location
    Prague
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-5684-8
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2013.0001
  • Filename
    6725000