• DocumentCode
    3096864
  • Title

    Optimization of transverse oscillating fields for vector velocity estimation with convex arrays

  • Author

    Jensen, John A.

  • Author_Institution
    Dept. of Electr. Eng., Tech. Univ. of Denmark, Lyngby, Denmark
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    1753
  • Lastpage
    1756
  • Abstract
    A method for making Vector Flow Images using the transverse oscillation (TO) approach on a convex array is presented. The paper presents optimization schemes for TO fields for convex probes and evaluates their performance using Field II simulations and measurements using the SARUS experimental scanner. A 3 MHz 192 elements convex array probe (pitch 0.33 mm) is used in both simulations and measurements. An F-number of 5 is used in transmit and two 32 element wide peaks are used in receive separated by 96 elements between peaks. Parabolic velocity profiles are simulated at beam-to-flow angles from 90 to 45 degrees in steps of 15 degrees. The optimization routine changes the lateral oscillation period λx to yield the best possible estimates based on the energy ratio between positive and negative spatial frequencies in the ultrasound field. The basic equation for λx gives 1.14 mm at 40 mm, and 1.51 mm from the simulated point spread function. This results in a bias of 35% as λx directly scales the estimated velocities. Optimizing the focusing yields a λx of 1.61 mm. The energy ratio is reduced from -12.8 dB to -20.1 dB and the spectral bandwidth from 115.1 m-1 to 96.5 m-1. λx is maintained between 1.47 and 1.70 mm from 25 mm to 70 mm and is increased to 2.8 mm at a depth of 100 mm. Parabolic profiles are estimated using 16 emissions. The optimization gives a reduction in std. from 8.5% to 5.9% with a reduction in bias from 35% to 1.02% at 90 degrees (transverse flow) at a depth of 40 mm. Measurements have been made using the SARUS experimental ultrasound scanner and a BK Medical 8820e convex array transducer. Sixty-four elements was used in transmit and 2 × 32 elements in receive for creating a color flow map image of a flow rig phantom with a laminar, parabolic flow. At 75 degrees a bias of less than 1% was obtained.
  • Keywords
    acoustic field; optimisation; oscillations; ultrasonic imaging; ultrasonic transducer arrays; ultrasonic velocity; ultrasonics; convex array transducer; flow rig phantom; optimization; parabolic velocity profiles; transverse oscillating fields; ultrasound field; ultrasound focusing; ultrasound scanner; vector flow images; vector velocity estimation; Estimation; Focusing; Optimization; Oscillators; Standards; Ultrasonic imaging; Vectors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2013 IEEE International
  • Conference_Location
    Prague
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-5684-8
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2013.0447
  • Filename
    6725056