• DocumentCode
    3098657
  • Title

    Real time deconvolution of in-vivo ultrasound images

  • Author

    Jensen, John A.

  • Author_Institution
    Dept. of Electr. Eng., Tech. Univ. of Denmark, Lyngby, Denmark
  • fYear
    2013
  • fDate
    21-25 July 2013
  • Firstpage
    29
  • Lastpage
    32
  • Abstract
    The axial resolution in medical ultrasound is directly linked to the emitted ultrasound frequency, which, due to tissue attenuation, is selected based on the depth of scanning. The resolution is determined by the transducers impulse response, which limits the attainable resolution to be between one and two wavelengths. This can be improved by deconvolution, which increase the bandwidth and equalizes the phase to increase resolution under the constraint of the electronic noise in the received signal. A fixed interval Kalman filter based deconvolution routine written in C is employed. It uses a state based model for the ultrasound pulse and can include a depth varying pulse and spatially varying signal-to-noise ratio. An autoregressive moving average (ARMA) model of orders 8 and 9 is used for the pulse, and the ARMA parameters are determined as a function of depth using a minimum variance algorithm using averaging over several RF lines. In vivo data from a 3 MHz mechanically rotating probe is used and the received signal is sampled at 20 MHz and 12 bits. In-vivo data acquired from a 16th week old fetus is used along with a scan from the liver and right kidney of a 27 years old male. The axial resolution has been determined from the in-vivo liver image using the auto-covariance function. From the envelope of the estimated pulse the axial resolution at Full-Width-Half-Max is 0.581 mm corresponding to 1.13 λ at 3 MHz. The algorithm increases the resolution to 0.116 mm or 0.227 λ corresponding to a factor of 5.1. The basic pulse can be estimated in roughly 0.176 seconds on a single CPU core on an Intel i5 CPU running at 1.8 GHz. An in-vivo image consisting of 100 lines of 1600 samples can be processed in roughly 0.1 seconds making it possible to perform real-time deconvolution on ultrasound data by using dual or quad core CPUs for frame-rates of 20-40 Hz.
  • Keywords
    Kalman filters; biological tissues; biomedical transducers; biomedical ultrasonics; deconvolution; image denoising; image resolution; kidney; medical image processing; obstetrics; ultrasonic imaging; ultrasonic transducers; ARMA model; ARMA parameters; In vivo data; Intel i5 CPU; autocovariance function; autoregressive moving average model; axial resolution; depth varying pulse; dual core CPU; electronic noise; fixed interval Kalman filter based deconvolution routine; frequency 1.8 GHz; frequency 20 Hz to 40 Hz; frequency 3 MHz; full-width-half-max; in-vivo liver imaging; in-vivo ultrasound imaging; mechanical rotating probe; minimum variance algorithm; old fetus; pulse resolution; quad core CPU; real time deconvolution; spatial varying signal-noise ratio; state based model; tissue attenuation; transducer impulse response; ultrasound frequency; ultrasound pulse; Deconvolution; Estimation; Image resolution; Signal resolution; Signal to noise ratio; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2013 IEEE International
  • Conference_Location
    Prague
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4673-5684-8
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2013.0008
  • Filename
    6725143