Transducer excitation with switched-mode encoded signals for harmonic and amplitude control verified using the Leach model
Author
Ingham, Robert H. ; James, Rob ; Smith, Peter ; Cowell, David M. J. ; Freear, Steven
Author_Institution
Ultrasound Group, Univ. of Leeds, Leeds, UK
fYear
2013
fDate
21-25 July 2013
Firstpage
457
Lastpage
460
Abstract
An excitation method to reduce harmonic content in the third harmonic was verified utilizing SPICE modeling. The SPICE model incorporated a MOSFET model and the Leach model to form a multi-level switch-mode pulser circuit. The pulser circuit was driven with a Harmonic Reduction PWM excitation sequence and a stepped excitation sequence with a fundamental frequency of 2 Mhz. An FFT of the excitation sequences was compared to verify the performance of the MOSFETs with the excitation sequences. It was found that at the third harmonic, the harmonic content was reduced by 22.2 dB.
Keywords
MOSFET; SPICE; piezoelectric transducers; ultrasonic transducers; Leach model; MOSFET model; SPICE modeling; amplitude control; excitation sequences; frequency 2 MHz; harmonic control; harmonic reduction PWM excitation sequence; multilevel switch mode pulser circuit; stepped excitation sequence; switched mode encoded signals; third harmonic; transducer excitation; Acoustics; Harmonic analysis; Integrated circuit modeling; MOSFET; SPICE; Transducers; Ultrasonic imaging;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2013 IEEE International
Conference_Location
Prague
ISSN
1948-5719
Print_ISBN
978-1-4673-5684-8
Type
conf
DOI
10.1109/ULTSYM.2013.0118
Filename
6725255
Link To Document