• DocumentCode
    3102189
  • Title

    DigitalSTROM®: A centralized PLC topology for home automation and energy management

  • Author

    Dickmann, Georg

  • Author_Institution
    Aizo AG Schweiz, Schlieren, Switzerland
  • fYear
    2011
  • fDate
    3-6 April 2011
  • Firstpage
    352
  • Lastpage
    357
  • Abstract
    A digitalSTROM® system is based on concentrators that reside in the distribution board, act as power-meters for the individual distribution circuits and communicate with individual nodes installed within a home over differently modulated up- and downstream channels. This paper presents the advantages of the digitalSTROM® topology, elaborates on the modulation schemes that have been optimized to lend themselves to miniaturized implementation and quantifies the level of interference caused by typical home appliances.
  • Keywords
    carrier transmission on power lines; energy management systems; home automation; power meters; centralized PLC topology; digitalSTROM system; distribution board; energy management; home appliance; home automation; individual distribution circuits; power-meters; Attenuation; Electrical products; Frequency shift keying; Impedance; Interference; Power cables; Transmitters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Line Communications and Its Applications (ISPLC), 2011 IEEE International Symposium on
  • Conference_Location
    Udine
  • Print_ISBN
    978-1-4244-7751-7
  • Electronic_ISBN
    978-1-4244-7749-4
  • Type

    conf

  • DOI
    10.1109/ISPLC.2011.5764421
  • Filename
    5764421