Title :
Research on Temperature Field Measuring of Oxygen Propane
Author_Institution :
Dept. of Electr. Inf., Taiyuan Univ. of Sci. & Technol., Taiyuan, China
Abstract :
By substituting alumina particles for soot created in burning flame and using the three-color method, the temperature field of the oxygen propane is calculated based on the image taken by CCD and digital image processing technology. The results show that the method using alumina particles and three-color to measure temperature field of the oxygen propane is feasible.
Keywords :
CCD image sensors; image colour analysis; CCD image processing; digital image processing; oxygen propane; temperature field measurement; three color method; Atmospheric measurements; Charge coupled devices; Combustion; Fires; Optical variables measurement; Particle measurements; Temperature measurement; CCD; image processing; oxygen propane flame; temperature field;
Conference_Titel :
Computational Aspects of Social Networks (CASoN), 2010 International Conference on
Conference_Location :
Taiyuan
Print_ISBN :
978-1-4244-8785-1
DOI :
10.1109/CASoN.2010.144