• DocumentCode
    3105036
  • Title

    The correction of voltage sag on mining machines utilising a locally connected STATCOM in the IDEA lab

  • Author

    Rowe, Christopher N. ; Summers, T.J. ; Betz, R.E. ; Gay, David J.

  • Author_Institution
    Sch. of Electr. Eng. & Comput. Sci., Univ. of Newcastle, Newcastle, NSW, Australia
  • fYear
    2013
  • fDate
    Sept. 29 2013-Oct. 3 2013
  • Firstpage
    1
  • Lastpage
    6
  • Abstract
    In mining power systems, voltage sag caused by the starting currents of direct-on-line asynchronous machines can affect adjacent plant. This paper utilises a STATCOM installed on the terminals of an asynchronous machine, implementing a voltage support algorithm, to correct voltage sag. Experimental results are presented from a three phase, low voltage system showing the local correction of voltage sag. Further, this paper presents the first experiment conducted in the IDEA laboratory, an initiative between CRCMining and the Power Group at the University of Newcastle, Australia.
  • Keywords
    asynchronous machines; mining; power supply quality; static VAr compensators; Australia; CRCMining; IDEA lab; Power Group; STATCOM; University of Newcastle; direct-on-line asynchronous machines; low voltage system; mining machines; mining power systems; voltage sag correction; voltage support algorithm; Australia; Automatic voltage control; Educational institutions; Fuel processing industries; Power electronics; Power system stability; Voltage fluctuations; Mining Machines; Power Electronics; STATCOM; Voltage Support;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Engineering Conference (AUPEC), 2013 Australasian Universities
  • Conference_Location
    Hobart, TAS
  • Type

    conf

  • DOI
    10.1109/AUPEC.2013.6725447
  • Filename
    6725447