DocumentCode :
3108545
Title :
Power factor correction of linear and nonlinear loads employing a single phase active power filter based on a full-bridge current source inverter controlled through the sensor of the AC mains current
Author :
Pottker de Souza, F. ; Barbi, Ivo
Author_Institution :
Dept. of Electr. Eng., Univ. Fed. de Santa Catarina, Florianapolis, Brazil
Volume :
1
fYear :
1999
fDate :
36373
Firstpage :
387
Abstract :
This paper introduces a new technique to control a single phase active power filter based on a full-bridge current source inverter. The active power filter is controlled through the sensor of the input current, allowing the compensation for current harmonics and phase displacement of any linear, nonlinear and multiple loads. Theoretical analysis, design procedure, simulation and experimental results are provided
Keywords :
active filters; bridge circuits; compensation; invertors; load (electric); power factor correction; power harmonic filters; AC mains current sensor; current harmonics compensation; design procedure; full-bridge current source inverter; input current sensor; linear loads; multiple loads; nonlinear loads; phase displacement; power factor correction; simulation; single phase active power filter; Active filters; Inductance; Inverters; Power electronics; Power factor correction; Power harmonic filters; Power system harmonics; Reactive power; Switches; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power Electronics Specialists Conference, 1999. PESC 99. 30th Annual IEEE
Conference_Location :
Charleston, SC
ISSN :
0275-9306
Print_ISBN :
0-7803-5421-4
Type :
conf
DOI :
10.1109/PESC.1999.789034
Filename :
789034
Link To Document :
بازگشت