DocumentCode :
3111125
Title :
Matching a pulsed power modulator to a corona plasma reactor
Author :
Winands, G.J.J. ; Pemen, A.J.M. ; van Heesch, E.J.M. ; Liu, Z. ; Yan, K.
Author_Institution :
Eindhoven University of Technology, Dept. of Electrical Engineering, P.O.Box 513, 5600 MB Eindhoven, Netherlands
Volume :
1
fYear :
2007
fDate :
17-22 June 2007
Firstpage :
587
Lastpage :
590
Abstract :
In this paper, the matching between the a pulsed power modulator and a corona plasma reactor is discussed. The matching is expressed as the energy transfer efficiency between the modulator and the reactor. The criterion for optimal matching between a source and a load is that the output impedance of the source is equal to the load impedance. When trying to match a pulsed power modulator to a plasma reactor this criterion is difficult to obey since the load impedance changes rapidly before, during and after plasma generation. To simulate the response of the load as function of the voltage pulse, an equivalent circuit is used. Measurements will be presented to verify the derived model. Guidelines to optimize the matching between the modulator and reactor are derived.
Keywords :
Corona; Energy exchange; Impedance; Inductors; Optimal matching; Plasma measurements; Plasma simulation; Plasma sources; Power generation; Pulse modulation;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 2007 16th IEEE International
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0913-6
Electronic_ISBN :
978-1-4244-0914-3
Type :
conf
DOI :
10.1109/PPPS.2007.4651911
Filename :
4651911
Link To Document :
بازگشت