DocumentCode :
3112816
Title :
Fault tolerant control using an admissible model matching approach
Author :
Staroswiecki, M.
Author_Institution :
Ecole Polytechnique Universitaire de Lille, University of Lille I, 59655 Villeneuve d´´Ascq cedex.
fYear :
2005
fDate :
12-15 Dec. 2005
Firstpage :
2421
Lastpage :
2426
Abstract :
In the pseudo-inverse method (PIM) the Frobenius norm based distance between the closed loop model of the faulty system and some reference model is minimized. Stability issues are considered in the Modified PIM (MPIM). This paper proposes to use a set of admissible models, rather than searching for an optimal one which does not provide any stability / performance guarantee. The approach allows to characterize the set of recoverable faults, and to associate some robustness property with the fault adaptation scheme.
Keywords :
Aerospace control; Attenuation; Closed loop systems; Control systems; Fault tolerance; Optimal control; Predictive control; Predictive models; Robustness; Stability;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Decision and Control, 2005 and 2005 European Control Conference. CDC-ECC '05. 44th IEEE Conference on
Print_ISBN :
0-7803-9567-0
Type :
conf
DOI :
10.1109/CDC.2005.1582525
Filename :
1582525
Link To Document :
بازگشت