• DocumentCode
    3114864
  • Title

    Characterization of a Xenon plasma electron flood gun on a GSD-200E 2 high current implanter using QBD, FLASH, SPIDER, and CHARMTM-2 wafers

  • Author

    Kopalidis, Peter ; Erokhin, Yuri ; Santiesteban, Ramon ; Soncini, Valter

  • Author_Institution
    Axcelis Technol. Inc., Beverly, MA, USA
  • fYear
    2000
  • fDate
    2000
  • Firstpage
    554
  • Lastpage
    557
  • Abstract
    An enhanced xenon plasma electron flood gun (PEF-Xe) used in a GSD-200E2 ion implanter is characterized by means of various wafer test structures. High dose/beam current implants are performed under different PEF settings to investigate the charge neutralization capability of the tool. QBD, FLASH, SPIDER and CHARMTM -2 test structures are used to explore a range of operating conditions for high beam current arsenic implants
  • Keywords
    MOSFET; arsenic; electron guns; electron sources; flash memories; ion implantation; plasma materials processing; semiconductor device measurement; semiconductor device testing; semiconductor doping; xenon; CHARM-2 wafers; FLASH wafers; GSD-200E2 high current implanter; PEF-Xe; QBD wafers; SPIDER wafers; Xe; charge neutralization capability; enhanced Xenon plasma electron flood gun; flash memory; high beam current arsenic implants; high dose/beam current implants; nmos transistor; operating condition; pmos transistors; wafer test structures; xenon plasma electron flood gun; Antenna measurements; Design for quality; Electrons; Flash memory; Floods; Implants; Plasmas; Testing; Threshold voltage; Xenon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ion Implantation Technology, 2000. Conference on
  • Conference_Location
    Alpbach
  • Print_ISBN
    0-7803-6462-7
  • Type

    conf

  • DOI
    10.1109/.2000.924212
  • Filename
    924212