• DocumentCode
    3116347
  • Title

    Basic measurement sites, methods, and associated errors

  • Author

    Heirman, Don

  • Author_Institution
    Don Heirman Consultants, Lincroft, NJ
  • fYear
    2008
  • fDate
    18-22 Aug. 2008
  • Firstpage
    1
  • Lastpage
    10
  • Abstract
    This article consists of power point presentation on EMC test facilities. The topics dealt include reverberation chamber testing, electromagnetic absorber, spectrum analyser, antenna calibration, immunity testing and radiation pattern.
  • Keywords
    antenna radiation patterns; antenna testing; calibration; electromagnetic compatibility; electromagnetic wave absorption; immunity testing; measurement errors; reverberation chambers; spectral analysers; EMC test facilities; antenna calibration; electromagnetic absorber; immunity testing; measurement errors; radiation pattern; reverberation chamber testing; spectrum analyser; Antenna measurements; Calibration; Electromagnetic analysis; Electromagnetic compatibility; Electromagnetic measurements; Electromagnetic radiation; Immunity testing; Pattern analysis; Reverberation chamber; Test facilities;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electromagnetic Compatibility, 2008. EMC 2008. IEEE International Symposium on
  • Conference_Location
    Detroit, MI
  • Print_ISBN
    978-1-4244-1699-8
  • Electronic_ISBN
    978-1-4244-1698-1
  • Type

    conf

  • DOI
    10.1109/ISEMC.2008.4652176
  • Filename
    4652176