• DocumentCode
    3117418
  • Title

    A study of corona discharge and surface tracking in the intermediate voltage range 2 to 3 kVAC

  • Author

    Krause, Marcella J.

  • Author_Institution
    ELTEK Int. Corp., St. Charles, MO, USA
  • fYear
    1989
  • fDate
    25-28 Sep 1989
  • Firstpage
    88
  • Lastpage
    92
  • Abstract
    Laboratory testing of motorette specimens showed that specimens failed in a matter of minutes when subjected to test voltages of 2300 VAC to 2500 VAC. A study was designed and implemented to determine the mode of failure and identify the cause. The author presents the steps taken, the information learned at each step, and the results of this evaluation. It was shown that the cause of failure was a combination of a corona-type discharge and the related surface tracking. A direct relationship was also found between specimen failure and moisture, physical design of the specimen, environment, and applied voltage
  • Keywords
    corona; failure analysis; insulation testing; machine insulation; surface discharges; 2300 to 2500 V; applied voltage; corona discharge; corona-type discharge; environment; intermediate voltage range; laboratory testing; mode of failure; moisture; motor test models; motorette specimens; physical design; surface tracking; test voltages; Cable insulation; Corona; Dielectrics and electrical insulation; Insulation life; Laboratories; Moisture; Power transformer insulation; Surface discharges; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Electronics Insulation Conference, 1989. Chicago '89 EEIC/ICWA Exposition., Proceedings of the 19th
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/EEIC.1989.208199
  • Filename
    208199