Title :
Investigation of an Optimum Sampling Interval for a Local Clock TIE Model with an Unbiased FIR Filtering Algorithm
Author :
Munoz-Diaz, Jorge ; Shmaliy, Yuriy S. ; Arceo-Miquel, Luis ; Ibarra-Manzano, Oscar
Author_Institution :
FIMEE, Guanajuato Univ., Salamanca
Abstract :
An investigation of the optimal time step (sampling interval) is provided for the time interval error (TIE) model of a local crystal clock in GPS-based timekeeping. For the sawtooth noise of a receiver, the local clock states are estimated employing an unbiased finite impulse response (FIR) filtering algorithm. We exploit the local crystal clock imbedded to the Stanford Frequency Counter SR620. The measurements are provided using the SynPaQ III GPS Sensor as a timing receiver and rubidium clock (SR625) as a reference source of time for the crystal clock
Keywords :
FIR filters; Global Positioning System; clocks; measurement errors; sampling methods; time measurement; GPS-based timekeeping; SR620; SR625; Stanford frequency counter; SynPaQ III GPS Sensor; finite impulse response; local clock TIE model; local crystal clock; optimum sampling interval; receiver sawtooth noise; rubidium clock; time interval error; timing receiver; unbiased FIR filtering algorithm; Clocks; Counting circuits; Filtering algorithms; Finite impulse response filter; Frequency; Global Positioning System; Sampling methods; State estimation; Time measurement; Timing;
Conference_Titel :
International Frequency Control Symposium and Exposition, 2006 IEEE
Conference_Location :
Miami, FL
Print_ISBN :
1-4244-0074-0
Electronic_ISBN :
1-4244-0074-0
DOI :
10.1109/FREQ.2006.275455