DocumentCode :
3119962
Title :
Experimental validation of a leakage and fill-level estimation method for vented tanks
Author :
Brunnader, Rudolf ; Holler, Gert
Author_Institution :
Inst. of Electr. Meas. & Meas. Signal Process., Graz Univ. of Technol., Graz, Austria
fYear :
2011
fDate :
Nov. 28 2011-Dec. 1 2011
Firstpage :
395
Lastpage :
398
Abstract :
Commonly used pneumatic fill-level sensing methods are typically limited by the requirement of a perfectly sealed tank system. In the paper, we present first experimental results for a model-based approach that is capable of distinguishing between the influences of varying free volume inside the tank and of small ventilation holes and leakages in the tank hull. The results are obtained by considering the estimated values of the lossless parameters in the equivalent circuit model that correspond to the actual free volume and leakage magnitude.
Keywords :
equivalent circuits; level measurement; tanks (containers); volume measurement; acoustic volume measurement; equivalent circuit model; experimental validation; fill-level estimation method; leakage method; lossless parameters; pneumatic fill-level sensing methods; vented tanks; Acoustics; Equivalent circuits; Inductance; Integrated circuit modeling; Sensors; Ventilation; Volume measurement; Acoustic volume measurement; fill-level measurement; leakage detection; pneumatic sensing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensing Technology (ICST), 2011 Fifth International Conference on
Conference_Location :
Palmerston North
ISSN :
2156-8065
Print_ISBN :
978-1-4577-0168-9
Type :
conf
DOI :
10.1109/ICSensT.2011.6137007
Filename :
6137007
Link To Document :
بازگشت