DocumentCode :
3121277
Title :
Electrical interference with pickup coil in induction magnetometer
Author :
Tashiro, Kunihisa ; Wakiwaka, Hiroyuki ; Inoue, Shin-ichiro
Author_Institution :
Spin Device Technol. Center, Shinshu Univ., Nagano, Japan
fYear :
2011
fDate :
Nov. 28 2011-Dec. 1 2011
Firstpage :
85
Lastpage :
88
Abstract :
In this paper, we consider electrical interference with pickup coil in an induction magnetometer. By using a dummy load in place the pickup coil, we confirm that there is no significant electrical interference with a differential-input type current-to-voltage converter. In order to reveal electrical interference with the pickup coil, we investigate the output voltage of the magnetometer as grounding condition parameters. From the number of experimental considerations, we formulate a suitable condition to solve the electrical interference problem.
Keywords :
coils; convertors; interference; magnetometers; differential input type current-to-voltage converter; dummy load; electrical interference; induction magnetometer; pickup coil; Coils; Grounding; Interference; Joining processes; Magnetic field measurement; Magnetometers; Voltage measurement; Induction magnetometer; current-to-voltage converter; electrical interference; grounding condition; pickup coil;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Sensing Technology (ICST), 2011 Fifth International Conference on
Conference_Location :
Palmerston North
ISSN :
2156-8065
Print_ISBN :
978-1-4577-0168-9
Type :
conf
DOI :
10.1109/ICSensT.2011.6137074
Filename :
6137074
Link To Document :
بازگشت