DocumentCode :
3121374
Title :
Dc breakdown voltage of carbon dioxide medium under needle to plane electrode
Author :
Takade, M. ; Tanaka, K. ; Uemura, A. ; Roy, B.C. ; Kiyan, T. ; Namihira, T. ; Sasaki, M. ; Akiyama, H. ; Goto, M. ; Hara, M.
Author_Institution :
Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, 860-8555, JAPAN
Volume :
2
fYear :
2007
fDate :
17-22 June 2007
Firstpage :
1644
Lastpage :
1647
Abstract :
This paper reports the experimental results on the corona onset voltage and breakdown voltage by positive and negative dc discharges in carbon dioxide medium within the pressure range of 0.1 to 15MPa under the needle to plane electrode. From the experimental results of dc discharge, negative corona discharges are observed more clearly in liquid and supercritical phase than in gas phase of carbon dioxide. However, in our experimental condition, positive corona discharge was not found for dc discharges. The breakdown mechanism in liquid can be classified into two categories on account of the bubble-triggered formation.
Keywords :
Breakdown voltage; Carbon dioxide; Chemical reactors; Corona; Electric breakdown; Electrodes; Needles; Plasma temperature; Production; Solvents;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Pulsed Power Conference, 2007 16th IEEE International
Conference_Location :
Albuquerque, NM
Print_ISBN :
978-1-4244-0913-6
Electronic_ISBN :
978-1-4244-0914-3
Type :
conf
DOI :
10.1109/PPPS.2007.4652505
Filename :
4652505
Link To Document :
بازگشت