• DocumentCode
    3121458
  • Title

    Calibration report of the SHARAD instrument

  • Author

    Croci, R. ; Fois, F. ; Flamini, E. ; Mecozzi, R. ; Seu, R.

  • Author_Institution
    Alcatel Alenia Space Italia S.p.A. Business Unit Observation Systems & Radar, Via Saccomuro 24, 00131, Rome, Italy, renato.croci@aleniaspazio.it
  • fYear
    2007
  • fDate
    27-29 June 2007
  • Firstpage
    241
  • Lastpage
    245
  • Abstract
    The Mars Shallow Radar Sounder (SHARAD) is an HF (20 MHz) Sounding Radar embarked onboard the Mars Reconnaissance Orbiter (MRO) spacecraft. SHARAD on-ground calibration activities have been limited to the characterization of the SEB (SHARAD Electronic Box), not having been possible to perform extensive characterization of the flight antenna nor end-to-end calibrations on ground. Scope of the present document is to define the activities to be carried out in-flight in order to ensure SHARAD products calibration. The calibration needs are assessed and an overall calibration strategy is then defined, leading to the identification of the data sets to be collected and relevant processing to be applied. The document also address how to exploit the available calibration data (from both on-ground and in-flight calibration) to correct SHARAD products, and the organization of the calibration database.
  • Keywords
    Aerospace electronics; Calibration; Databases; Hafnium; Instruments; Mars; Radar antennas; Reconnaissance; Space vehicles; Spaceborne radar; active radiometric calibration; passive radiometric calibration; penetrating radar; radar sounder;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Advanced Ground Penetrating Radar, 2007 4th International Workshop on
  • Conference_Location
    Aula Magna Partenope
  • Print_ISBN
    1-4244-0886-5
  • Electronic_ISBN
    1-4244-0886-5
  • Type

    conf

  • DOI
    10.1109/AGPR.2007.386560
  • Filename
    4278883