DocumentCode
3121559
Title
CAPEX-U device - driver for discharge-based soft x-ray lasers with λ ≪ 15 nm
Author
Kolacek, K. ; Frolov, O. ; Prukner, V. ; Schmidt, J. ; Straus, J.
Author_Institution
Institute of Plasma Physics, Academy of Sciences of the Czech Republic, v.v.i., Za Slovankou 3, 182 00 Prague 8, Czech Republic
Volume
2
fYear
2007
fDate
17-22 June 2007
Firstpage
1683
Lastpage
1686
Abstract
CAPEX-U device is a pulse-power apparatus capable to deliver a short-circuit discharge current ∼120 kA in a quarter-period ∼100 ns. Its characteristic features are direct optical access to both discharge electrodes, laser triggering of the main spark gap (for exact synchronization of detectors and applications), and larger transverse dimensions (for higher flexibility in applied voltage, and in pre-pulse application). Our first experiments with nitrogen-filled capillary (that should amplify spontaneous emission of Balmer-alpha transition of H-like N due to recombination pumping) as well as experiments with exploding wire in locally compressed water (that should amplify spontaneous emission of one line of Ni-like Ag - due to excitation pumping) are described.
Keywords
Electrodes; Laser transitions; Optical pulses; Optical pumping; Pump lasers; Sparks; Spontaneous emission; Stimulated emission; Voltage; X-ray lasers;
fLanguage
English
Publisher
ieee
Conference_Titel
Pulsed Power Conference, 2007 16th IEEE International
Conference_Location
Albuquerque, NM
Print_ISBN
978-1-4244-0913-6
Electronic_ISBN
978-1-4244-0914-3
Type
conf
DOI
10.1109/PPPS.2007.4652514
Filename
4652514
Link To Document