DocumentCode
3125205
Title
Thermal modeling of micro-hotplates for integrated sensor applications
Author
Wong, Darwin T W ; Chan, Philip C.H. ; Sheng, Lie-yi ; Sin, Johnny K O
Author_Institution
Dept. of Electr. & Electron. Eng., Hong Kong Univ. of Sci. & Technol., Kowloon, Hong Kong
fYear
1997
fDate
35672
Firstpage
149
Lastpage
152
Abstract
Micromachined micro-hotplate (MHP) is used in integrated gas sensors to heat SnO2 sensing film to the high operating temperature with milli-watts of power. This paper reports a detailed thermal modeling study of the MHP using 3-D finite element analysis. Three MHP structures were analyzed. Their thermal characteristics were compared
Keywords
finite element analysis; gas sensors; microsensors; thermal analysis; tin compounds; 3D finite element analysis; SnO2; SnO2 film; integrated gas sensor; micromachined micro-hotplate; thermal model; Boundary conditions; Bridges; Conducting materials; Etching; Finite element methods; Gas detectors; Heat transfer; Silicon; Steady-state; Temperature sensors; Thermal conductivity; Thermal sensors;
fLanguage
English
Publisher
ieee
Conference_Titel
Electron Devices Meeting, 1997. Proceedings., 1997 IEEE Hong Kong
Print_ISBN
0-7803-3802-2
Type
conf
DOI
10.1109/HKEDM.1997.642353
Filename
642353
Link To Document