    This paper investigates the specific contributions of the pre-ejection period (PEP) and pulse transit time (PTT) for blood pressure estimation based on the pulse wave methodology. We show that in short-term physical stress tests, PEP dominates PTT variations raising the question of a suitable blood pressure calibration. A model using a generalized pulse wave velocity achieves acceptable accuracy for systolic blood pressure estimation, given our experimental conditions
  • Keywords
    biomechanics; blood pressure measurement; calibration; patient monitoring; bicycle test; blood pressure calibration; cuffless estimation; generalized pulse wave velocity; preejection period; pulse transit time; pulse wave methodology; short-term physical stress exercise; systolic blood pressure estimation; Bicycles; Biomedical monitoring; Blood pressure; Calibration; Electrocardiography; Fingers; Hypertension; Pressure measurement; Pulse measurements; Testing; blood pressure calibration; blood pressure regulation; physical stress; pre-ejection period; pulse transit-time;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1557-170X
  • Print_ISBN
    1-4244-0032-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2006.260275
  • Filename
    4462948