• DocumentCode
    3133573
  • Title

    Detection of underfill epoxy defects in flip chip packages with the aid of SAM, parallel polishing and FIB

  • Author

    Tang, T.N. ; Heng, H.C. ; Chan, S.Y. ; Hiew, Marshall

  • Author_Institution
    Dept. of Quality Eng., Adv. Micro Devices, Penang, Malaysia
  • fYear
    1999
  • fDate
    1999
  • Firstpage
    50
  • Lastpage
    54
  • Abstract
    This paper describes the techniques of scanning acoustic microscopy (SAM), parallel polishing and focused ion beam (FIB) cross-sectioning used to detect and identify underfill defects in C4 flip chip packages
  • Keywords
    acoustic microscopy; encapsulation; flip-chip devices; focused ion beam technology; integrated circuit interconnections; integrated circuit packaging; integrated circuit reliability; integrated circuit testing; polishing; C4 flip chip packages; FIB; FIB cross-sectioning; SAM; flip chip packages; focused ion beam cross-sectioning; parallel polishing; scanning acoustic microscopy; underfill defects; underfill epoxy defect detection; underfill epoxy defects; Acoustic devices; Acoustic signal detection; Acoustical engineering; Flip chip; Integrated circuit packaging; Integrated circuit technology; Ion beams; Laboratories; Microscopy; Silicon;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits, 1999. Proceedings of the 1999 7th International Symposium on the
  • Print_ISBN
    0-7803-5187-8
  • Type

    conf

  • DOI
    10.1109/IPFA.1999.791303
  • Filename
    791303