• DocumentCode
    3133850
  • Title

    New Methodology For Preventing Pressure Ulcers Using Actimetry and Autonomous Nervous System Recording

  • Author

    Meffre, R. ; Gehin, C. ; Schmitt, P.M. ; De Oliveira, F. ; Dittmar, A.

  • Author_Institution
    Biomed. Microsensors Dept., Inst. Nat. des Sci. Appliquees de Lyon, Villeurbanne
  • fYear
    2006
  • fDate
    Aug. 30 2006-Sept. 3 2006
  • Firstpage
    5563
  • Lastpage
    5566
  • Abstract
    Pressure ulcers constitute an important health problem. They affect lots of people with mobility disorder and they are difficult to detect and prevent because the damage begins on the muscle. This paper proposes a new approach to study pressure ulcers. We aim at developing a methodology to analyse the probability for a patient to develop a pressure ulcer, and that can detect risky situation. The idea is to relate the mobility disorder to autonomic nervous system (ANS) trouble. More precisely, the evaluation of the consequence of the discomfort on the ANS (stress induced by discomfort) can be relevant for the early detection of the pressure ulcer. Mobility is evaluated through movement measurement. This evaluation, at the interface between soft living tissues and any support has to consider the specificity of the human environment. Soft living tissues have non-linear mechanical properties making conventional rigid sensors non suitable for interface parameters measurement. A new actimeter system has been designed in order to study movements of the human body whatever its support while seating. The device is based on elementary active cells. The number of pressure cells can be easily adapted to the application. The spatial resolution is about 4cm2. In this paper, we compare activity measurement of a seated subject with his autonomic nervous system activity, recorded by E.motion device. It has been developed in order to record six parameters: skin potential, skin resistance, skin temperature, skin blood rate, instantaneous cardiac frequency and instantaneous respiratory frequency. The design, instrumentation, and first results are presented
  • Keywords
    biological tissues; biomechanics; biomedical equipment; biomedical measurement; muscle; neurophysiology; skin; E.motion device; actimetry; activity measurement; autonomous nervous system recording; elementary active cells; instantaneous cardiac frequency; instantaneous respiratory frequency; mobility disorder; movement measurement; muscle; nonlinear mechanical properties; pressure ulcers; skin blood rate; skin potential; skin resistance; skin temperature; soft living tissue; Autonomic nervous system; Frequency; Humans; Mechanical factors; Motion measurement; Muscles; Nervous system; Risk analysis; Skin; Stress;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1557-170X
  • Print_ISBN
    1-4244-0032-5
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2006.259352
  • Filename
    4463066