DocumentCode :
3137266
Title :
Cuffless and Noninvasive Tonometry Mean Arterial Pressure Measurement by Physiological Characteristics and Applied Pressure
Author :
Park, Mikyoung ; Kang, HeeJung ; Huh, Young ; Kim, Kyung-Chul
Author_Institution :
Bio-electron. Sensor Lab., Korea Electrotechnol. Res. Inst., Ansan
fYear :
2006
fDate :
Aug. 30 2006-Sept. 3 2006
Firstpage :
6418
Lastpage :
6421
Abstract :
We developed a cuffless and noninvasive measurement technique of blood pressure using tonometric pressure sensor. With observation that the maximum value of a pulse pressure is not obtained at mean arterial pressure (MAP), we have figured out MAP based on the physiological characteristic including the elasticity of wrist tissue, the depth of blood vessel. Through an analysis of 198 clinic data, we have induced the regression equation of the MAP. The probability of the elasticity, depth and APM to explain MAP was 92.1%. The mean difference and the standard deviation between the MAP predicted from the regression equation and the MAP measured by commercial cuff type BP meter were Z-3.183 mmHg and 5.133 mmHg respectively. Comparing the results with the American national standard for electronic or automated sphygmomanometers, we can conclude that the results are quite reliable and promising. Detecting only one part of the body and using only one device are quite advantageous over other BP measurement technique. Our technique makes new way for the cuffless BP measurement
Keywords :
biomedical equipment; blood pressure measurement; blood vessels; elasticity; pressure sensors; regression analysis; American national standard for electronic sphygmomanometers; automated sphygmomanometers; blood pressure measurement technique; blood vessel; elasticity; noninvasive cuffless tonometry; noninvasive mean arterial pressure measurement; physiological characteristics; regression equation; tonometric pressure sensor; wrist tissue; Blood pressure; Blood vessels; Difference equations; Elasticity; Measurement standards; Measurement techniques; Noninvasive treatment; Pressure measurement; Sensor phenomena and characterization; Wrist;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2006. EMBS '06. 28th Annual International Conference of the IEEE
Conference_Location :
New York, NY
ISSN :
1557-170X
Print_ISBN :
1-4244-0032-5
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2006.260062
Filename :
4463280
Link To Document :
بازگشت