  • Title

    Unbalanced magnetic pull induced by leading wires of permanent magnet synchronous motor

  • Author

    Bi, Chao ; Phyu, Hla Nu ; Jiang, Quan

  • Author_Institution
    Data Storage Inst., A*Star, Singapore, Singapore
  • fYear
    2009
  • fDate
    15-18 Nov. 2009
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The leading wires of the armature winding may conduce the windings be asymmetric in permanent magnet synchronous motor (PMSM), and finally induce an additional unbalanced magnetic pull (UMP) in the motor operation. The influence of the UMP could be serious, especially in the operation of high speed PMSMs. The paper analyzes the reason inducing this special UMP, and effects of UMP to the motor operation. Several measures also proposed for weakening the influence of the UMP.
  • Keywords
    machine windings; permanent magnet motors; synchronous motors; wires (electric); armature winding; leading wires; motor operation; permanent magnet synchronous motor; unbalanced magnetic pull; Acoustic noise; Brushless DC motors; DC motors; Permanent magnet motors; Production; Rotors; Synchronous motors; Torque; Voltage; Wires; Permanent magnet synchronous motor; asymmetric winding; drive current; leading wire; spindle motor; unbalanced magnetic pull;