Title :
Unbalanced magnetic pull induced by leading wires of permanent magnet synchronous motor
Author :
Bi, Chao ; Phyu, Hla Nu ; Jiang, Quan
Author_Institution :
Data Storage Inst., A*Star, Singapore, Singapore
Abstract :
The leading wires of the armature winding may conduce the windings be asymmetric in permanent magnet synchronous motor (PMSM), and finally induce an additional unbalanced magnetic pull (UMP) in the motor operation. The influence of the UMP could be serious, especially in the operation of high speed PMSMs. The paper analyzes the reason inducing this special UMP, and effects of UMP to the motor operation. Several measures also proposed for weakening the influence of the UMP.
Keywords :
machine windings; permanent magnet motors; synchronous motors; wires (electric); armature winding; leading wires; motor operation; permanent magnet synchronous motor; unbalanced magnetic pull; Acoustic noise; Brushless DC motors; DC motors; Permanent magnet motors; Production; Rotors; Synchronous motors; Torque; Voltage; Wires; Permanent magnet synchronous motor; asymmetric winding; drive current; leading wire; spindle motor; unbalanced magnetic pull;
Conference_Titel :
Electrical Machines and Systems, 2009. ICEMS 2009. International Conference on
Conference_Location :
Tokyo
Print_ISBN :
978-1-4244-5177-7
Electronic_ISBN :
978-4-88686-067-5
DOI :
10.1109/ICEMS.2009.5382742