DocumentCode :
3142142
Title :
Development of the world´s largest hydrogen indirectly cooled turbine generator
Author :
Nagakura, Ken ; Otaka, Toru ; Kakiuchi, Mikio ; Gunji, Yuichiro ; Nakayama, Shinya ; Murata, Daisuke ; Kabata, Yasuo ; Hatano, Hiroshi
Author_Institution :
Toshiba Corp., Yokohama, Japan
fYear :
2009
fDate :
15-18 Nov. 2009
Firstpage :
1
Lastpage :
6
Abstract :
Water-cooled stator-winding generators are widely used for large capacity turbine generators of thermal power plant. However, simpler stator cooling system is preferred considering easy operation and maintenance and lower cost. Hydrogen indirectly cooled generator is one of the solution with expansion its capacity. TOSHIBA has developed, manufactured and tested 670 MVA hydrogen indirectly cooled generator. Meanwhile, higher efficiency is requested for turbine generators to reduce the global environment load. The developed generator has accomplished 99.1% of efficiency at shop test and will meet high efficiency demands. In this paper, applied technologies and shop test results of the large capacity hydrogen indirectly cooled generator are described.
Keywords :
thermal power stations; turbogenerators; apparent power 670 MVA; hydrogen indirectly cooled turbine generator; thermal power plant; Conductors; Cooling; Costs; Hydraulic turbines; Hydrogen; Maintenance; Manufacturing; Power generation; Stator windings; Testing; Efficiency; Hydrogen cooled; Turbine generator;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2009. ICEMS 2009. International Conference on
Conference_Location :
Tokyo
Print_ISBN :
978-1-4244-5177-7
Electronic_ISBN :
978-4-88686-067-5
Type :
conf
DOI :
10.1109/ICEMS.2009.5382940
Filename :
5382940
Link To Document :
بازگشت