CESR luminosity dependence on magnetic alignment
Author :
Holtzapple, R. ; Rice, D.
Author_Institution :
Lab. of Nucl. Studies, Cornell Univ., Ithaca, NY, USA
Abstract :
The Cornell electron-positron storage ring (CESR) luminosity has increased by a factor of >3 over the last 3 years with a peak luminosity of 8.0×1032 cm-2 sec-1 and a record integrated luminosity of 750 pb-1 for one month. This increase in luminosity is in part due to improved alignment of magnetic elements. Operation with a pretzel orbit in multiple bunch mode places particular importance on alignment because of the side effects of magnetic correctors. We report the improvements in alignment and estimate the effects on colliding beam performance
Keywords :
accelerator magnets; beam handling techniques; colliding beam accelerators; electron accelerators; storage rings; CESR luminosity dependence; Cornell electron-positron storage ring; colliding beam performance; magnetic alignment; magnetic correctors; magnetic elements; multiple bunch mode; pretzel orbit; Accelerator magnets; Colliding beam accelerators; Electromagnetic fields; Error correction; Extraterrestrial measurements; Laboratories; Magnetic resonance; Magnetic separation; Rotation measurement; Storage rings;
Conference_Titel :
Particle Accelerator Conference, 1999. Proceedings of the 1999
Conference_Location :
New York, NY
Print_ISBN :
0-7803-5573-3
DOI :
10.1109/PAC.1999.792116