• DocumentCode
    314546
  • Title

    Partial discharge corona pulses in air and air-solid interface

  • Author

    Zahra, Fathima ; Nema, R.S.

  • Author_Institution
    Fac. of Eng. & Appl. Sci., Memorial Univ. of Newfoundland, St. John´´s, Nfld., Canada
  • Volume
    1
  • fYear
    1997
  • fDate
    25-28 May 1997
  • Firstpage
    169
  • Abstract
    Insulation is one of the major requirements in any high voltage electrical system. The air-solid type interface forms a weak point for the partial discharges (PD) to occur. An understanding of the discharge process is contained in the PD pulse. The work is a study of the behaviour of the PD corona pulse shape in air and air-solid interface under different conditions. It is found that under varying conditions of the gap and overvoltages, there is a significant difference in the pulse shape
  • Keywords
    air gaps; charge measurement; corona; insulation testing; overvoltage; partial discharges; PMMA; air gap; air-solid interface; high voltage electrical system; insulation; overvoltages; partial discharge corona pulses; pulse shape; Breakdown voltage; Corona; Electrodes; Insulation; Noise measurement; Partial discharges; Pulse measurements; Pulse shaping methods; Resistors; Shape;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Computer Engineering, 1997. Engineering Innovation: Voyage of Discovery. IEEE 1997 Canadian Conference on
  • Conference_Location
    St. Johns, Nfld.
  • ISSN
    0840-7789
  • Print_ISBN
    0-7803-3716-6
  • Type

    conf

  • DOI
    10.1109/CCECE.1997.614817
  • Filename
    614817