Abstract
Insulation is one of the major requirements in any high voltage electrical system. The air-solid type interface forms a weak point for the partial discharges (PD) to occur. An understanding of the discharge process is contained in the PD pulse. The work is a study of the behaviour of the PD corona pulse shape in air and air-solid interface under different conditions. It is found that under varying conditions of the gap and overvoltages, there is a significant difference in the pulse shape
Keywords
air gaps; charge measurement; corona; insulation testing; overvoltage; partial discharges; PMMA; air gap; air-solid interface; high voltage electrical system; insulation; overvoltages; partial discharge corona pulses; pulse shape; Breakdown voltage; Corona; Electrodes; Insulation; Noise measurement; Partial discharges; Pulse measurements; Pulse shaping methods; Resistors; Shape;