Abstract :
The Navy is considering alternative power system architectures to traditional 60 Hz Medium Voltage Alternating Current (MVAC) power systems for shipboard operation. One alternative architecture being strongly considered for several reasons, is Medium-Voltage Direct Current (MVDC). With that consideration, comes the need for effective electrical fault risk prevention and mitigation. This paper explores the application of the recently invented “z-source dc circuit breaker” to a ship power system. Specifically, detailed simulation is used to study the response of the z-source breaker to faults at various locations in a ring-type dc power system. The addition of a central control unit results in ideal response in that only breakers necessary to isolate the fault remain open for all cases. This paper further explores implementation issues for eventual application to Navy ships.
Keywords :
circuit breakers; fault location; marine power systems; power system faults; power system protection; MVDC; central control unit; fault isolation; medium-voltage direct current power system; navy ships; ring-type dc power system; ship power system protection; z-source dc circuit breaker; Circuit faults; Fault location; Inverters; Marine vehicles; Power systems; Thyristors; Transient analysis; Circuit breaker; fault location; fault protection; power system protection; thyristor circuits;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electric Ship Technologies Symposium (ESTS), 2015 IEEE
Conference_Location :
Alexandria, VA
Print_ISBN :
978-1-4799-1856-0
Type :
conf
DOI :
10.1109/ESTS.2015.7157907
Filename :
7157907
Link To Document :
بازگشت