Title :
Single polyaniline-coated polystyrene latex particle on carbon microelectrode
Author :
Ke, Qiang ; He, Yi ; Wang, Shunhui ; Shi, Taihe
Abstract :
Large polyaniline-coated polystyrene (PANI-PS) latex particles (13μm in diameter) were used for measuring the limiting current of the suspension reaction on the carbon microelectrode (7μm in diameter). Two results were observed: one was no particle reaction on electrode, and the other was only one particle reacted on the electrode with the limiting current about 30pA. This value is almost the same as the limiting current that one particle was artificially put on the Pt microelectrode with the diameter of 20um when the potential applied. The color of polyaniline layer is in blue-green and the yellow-green indicates the occurrence of redox reaction.
Keywords :
chromatography; microelectrodes; oxidation; polymer blends; reduction (chemical); suspensions; C; PANI-PS latex particles; Pt; Pt microelectrode; carbon microelectrode; polyaniline layer color; redox reaction; single polyaniline-coated polystyrene latex particle; size 13 mum; size 20 mum; size 7 mum; suspension reaction limiting current; Carbon; Limiting; Microelectrodes; Petroleum; Scanning electron microscopy; Suspensions; carbon microelectrode; polyaniline; single particle; suspensions;
Conference_Titel :
Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on
Conference_Location :
XianNing
Print_ISBN :
978-1-61284-458-9
DOI :
10.1109/CECNET.2011.5768435