• DocumentCode
    315383
  • Title

    Multilevel STATCOM with third harmonic elimination on the DC link capacitor voltages

  • Author

    Mwinyiwiwa, Bakari ; Wolanski, Zbigniew ; Ooi, Boon-Teck

  • Author_Institution
    Dept. of Electr. Eng., McGill Univ., Montreal, Que., Canada
  • Volume
    1
  • fYear
    1997
  • fDate
    22-27 Jun 1997
  • Firstpage
    317
  • Abstract
    Simulation studies, confirmed by laboratory experiments, show that the undesirable third harmonic inherently present on the DC link capacitor voltages of multilevel converters can be eliminated by a 6-phase configuration in a shunt multilevel STATCOM. The principle can be extended to eliminate the residual sixth harmonic by configuring a 12-phase STATCOM
  • Keywords
    capacitors; harmonic distortion; power convertors; power system harmonics; static VAr compensators; 12-phase STATCOM; 6-phase configuration; DC link capacitor voltages; multilevel STATCOM; residual sixth harmonic elimination; shunt multilevel STATCOM; third harmonic elimination; Automatic voltage control; Bridge circuits; Capacitors; Control systems; Costs; Environmental economics; Flexible AC transmission systems; Laboratories; Power generation economics; Transformers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 1997. PESC '97 Record., 28th Annual IEEE
  • Conference_Location
    St. Louis, MO
  • ISSN
    0275-9306
  • Print_ISBN
    0-7803-3840-5
  • Type

    conf

  • DOI
    10.1109/PESC.1997.616743
  • Filename