DocumentCode
3160824
Title
New power factor correction and current harmonic mitigation for AC variable reluctance generator with DC excitation
Author
Tsukerman, Dimitry ; Rabinovici, Raul
Author_Institution
Dept. of Electr. & Comput. Eng., Ben-Gurion Univ. of the Negev, Beer-Sheva, Israel
fYear
2002
fDate
1 Dec. 2002
Firstpage
156
Lastpage
158
Abstract
The present paper proposes a new approach to compensate the inductive voltage drop on the internal inductance of the AC variable reluctance generator with DC excitation (AVARGED) and also to compensate the higher voltage harmonics produced in it. As a result, the output current and the associated output voltage on a resistive load are sinusoidal waves in phase with fundamental harmonic of the electro-motive force and without any higher harmonics.
Keywords
exciters; harmonic distortion; harmonics suppression; machine theory; power conversion harmonics; power factor correction; reluctance generators; AC variable reluctance generator; DC excitation; current harmonic mitigation; electro-motive force; higher voltage harmonics compensation; inductive voltage drop compensation; power factor correction; resistive load; sinusoidal output current; sinusoidal output voltage; AC generators; Coils; Equations; Inductance; Power factor correction; Power system harmonics; Reluctance generators; Rotors; Stators; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical and Electronics Engineers in Israel, 2002. The 22nd Convention of
Print_ISBN
0-7803-7693-5
Type
conf
DOI
10.1109/EEEI.2002.1178375
Filename
1178375