DocumentCode :
3161010
Title :
Automatic detection of the macula in the retinal fundus image by detecting regions with low pixel intensity
Author :
Tan, N.M. ; Wong, D.W.K. ; Liu, J. ; Ng, W.J. ; Zhang, Z. ; Lim, J.H. ; Tan, Z. ; Tang, Y. ; Li, H. ; Lu, S. ; Wong, T.Y.
Author_Institution :
Inst. for Infocomm Res., A*STAR, Singapore, Singapore
fYear :
2009
fDate :
2-4 Dec. 2009
Firstpage :
1
Lastpage :
5
Abstract :
This paper proposes a method to detect the macula in the retinal fundus image automatically. The method makes use of the optic disc height obtained from the ARGALI to define the region of interest. Regions of dark spots are then detected by finding the coordinates with the lowest pixel intensity and determining the average pixel neighbourhood intensities. These regions are ranked to determine the region containing the macula. This algorithm was tested on 162 images, and an accuracy of 98.8% was achieved. The results are promising for further development and use of this method in AMD studies and physiology localization.
Keywords :
eye; image classification; medical image processing; automatic detection; average pixel neighbourhood intensity; low-pixel intensity; macula; optic disc height; physiology localization; retinal fundus image; Blindness; Head; Image color analysis; Optical losses; Photoreceptors; Physiology; Pigmentation; Pixel; Retina; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Biomedical and Pharmaceutical Engineering, 2009. ICBPE '09. International Conference on
Conference_Location :
Singapore
Print_ISBN :
978-1-4244-4763-3
Electronic_ISBN :
978-1-4244-4764-0
Type :
conf
DOI :
10.1109/ICBPE.2009.5384075
Filename :
5384075
Link To Document :
بازگشت