• DocumentCode
    3161827
  • Title

    Development of a gas flow calibration facility by master meter method

  • Author

    Shengjie, Li ; Lijun, Sun ; Lixiao, Qi ; Lei, Qi ; Tao, Zhang

  • Author_Institution
    Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China
  • fYear
    2011
  • fDate
    16-18 April 2011
  • Firstpage
    2126
  • Lastpage
    2129
  • Abstract
    In this paper, a gas flow calibration facility by master meter method is developed. The paper deals with the design methods and working principle. The simulation of the confluence tube is analyzed. The pressure loss of pipe is calculated and the selection of the blower is analyzed. And then the distribution of the facility uncertainty is calculated. The uncertainty is better than 1% in the total flow range, and it is better than 0.5% at the fixed flow points.
  • Keywords
    calibration; design engineering; flow measurement; gas industry; pipe flow; pipes; blower selection; confluence tube; design method; gas flow calibration facility; master meter method; pipe; pressure loss; Calibration; Electron tubes; Fluid flow; Fluid flow measurement; Instruments; Publishing; Uncertainty; blower sections; confluence tube; flow measurement; gas flow calibration facility; pipe pressure loss; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Consumer Electronics, Communications and Networks (CECNet), 2011 International Conference on
  • Conference_Location
    XianNing
  • Print_ISBN
    978-1-61284-458-9
  • Type

    conf

  • DOI
    10.1109/CECNET.2011.5768934
  • Filename
    5768934