DocumentCode
3165007
Title
Development of flow stability experimental platform on water flow calibration facility
Author
Xiang, Qiu ; Lijun, Sun ; Bao, Li ; Tao, Zhang
Author_Institution
Tianjin Key Lab. of Process Meas. & Control, Tianjin Univ., Tianjin, China
fYear
2011
fDate
16-18 April 2011
Firstpage
2134
Lastpage
2137
Abstract
To study the flow stability of the flow calibration facility under different pressure stabilizing methods, analyze the influencing factors, and improve it. The paper develops a flow stability experimental platform. The flow range of it is 0.04~4 m3/h, the uncertainty of it is better than 0.05% (k=2). It proves that experimental platform works well and can reflect the difference of the flow stability under different pressure stabilizing methods according to the results of experiment on them.
Keywords
calibration; flow; flow stability experimental platform; pressure stabilizing method; water flow calibration facility; Calibration; Fluid flow; Fluid flow measurement; Inspection; Publishing; Stability analysis; Standardization; control system; flow calibration facility; flow measurement; flow stability; frequency control of motor speed;