DocumentCode
3169664
Title
Environmental qualification of insulation systems for nuclear applications
Author
Dymond, James H. ; Hare, Wayne W.
Author_Institution
Gen. Electr. Canada Inc., Peterborough, Ont., Canada
fYear
1995
fDate
18-21 Sep 1995
Firstpage
675
Lastpage
679
Abstract
For a recent contract, the user specified that the primary heat transport pump and the shutdown pump motors be environmentally qualified (EQ) for the applications. This meant that the complete motors, including the insulation, systems would be tested along the requirements set forth in IEEE 323, IEEE 334, and IEEE 344. The physical sizes of the machines prevented the actual units from being tested, and hence, component testing became necessary. To environmentally qualify a stator insulation system, including a loss of coolant accident (LOCA) toward the end of a 30 year insulation life, requires the manufacture and testing of statorettes. This paper discusses: (1) the types of problems which can be encountered in this type of exercise; (2) the testing and test results for both a 4 kV and a 13.2 kV insulation system; and (3) the results from testing to failure of the coils after the completion of the environmental qualification tests. Results of surge, hi-pot, polarization index, and partial discharge tests are presented
Keywords
electric breakdown; electric motors; fission reactor accidents; fission reactor cooling; insulation testing; life testing; machine insulation; machine testing; nuclear power stations; partial discharges; pumps; stators; 13.2 kV; 30 y; 4 kV; IEEE 323; IEEE 334; IEEE 344; LOCA; breakdown testing; coils; component testing; environmental qualification; hi-pot tests; insulation systems; loss of coolant accident; motor insulation testing; nuclear applications; partial discharge tests; polarization index tests; primary heat transport pump motor; shutdown pump motor; stator insulation system; statorettes; surge tests; Accidents; Contracts; Coolants; Heat pumps; Insulation life; Insulation testing; Manufacturing; Qualifications; Stators; System testing;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Electronics Insulation Conference, 1995, and Electrical Manufacturing & Coil Winding Conference. Proceedings
Conference_Location
Rosemont, IL
Print_ISBN
0-941783-15-4
Type
conf
DOI
10.1109/EEIC.1995.482515
Filename
482515