• DocumentCode
    3169684
  • Title

    Experience with compact epoxy-mica capacitors for rotating machine partial discharge detection

  • Author

    Goodeve, T.E. ; Stone, G.C. ; Macomber, L.

  • Author_Institution
    Iris Power Eng. Inc., Mississauga, Ont., Canada
  • fYear
    1995
  • fDate
    18-21 Sep 1995
  • Firstpage
    685
  • Lastpage
    689
  • Abstract
    Partial discharge pulses in operating motors and generators are often detected by either RF current transformers or high-voltage capacitors. Since the mid-1970s, an 80 pF capacitor has become popular for detecting partial discharges in hydrogenerators and, more recently, in motors. The 80 pF capacitor is made from XLPE power cable, resulting in an inexpensive, yet bulky, capacitor. A reliable 80 pF capacitor has now been developed using a mica and epoxy dielectric. The epoxy-mica capacitor is much more compact making it significantly easier to install. In fact, the installation time for the epoxy-mica capacitor is typically half the time needed to install the cable-type capacitor. More than 600 capacitors have now been installed on hydrogenerators, motors, and small turbine generators. This article discusses the design of the new capacitor, presents its electrical characteristics, and provides some examples of its installation
  • Keywords
    capacitors; electric breakdown; electric motors; epoxy insulation; hydroelectric generators; insulation testing; machine insulation; machine testing; mica; partial discharges; test equipment; turbogenerators; 80 pF; breakdown testing; design; electrical characteristics; epoxy-mica capacitors; hydrogenerator insulation tests; installation; motors; rotating machine partial discharge detection; test apparatus; turbine generators; Capacitors; Current transformers; Dielectrics; Hydraulic turbines; Partial discharges; Power cables; Pulse generation; Pulse transformers; Radio frequency; Rotating machines;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Electronics Insulation Conference, 1995, and Electrical Manufacturing & Coil Winding Conference. Proceedings
  • Conference_Location
    Rosemont, IL
  • Print_ISBN
    0-941783-15-4
  • Type

    conf

  • DOI
    10.1109/EEIC.1995.482517
  • Filename
    482517