• DocumentCode
    3173856
  • Title

    The effects of transmission errors in ECG real-timewavelet compression codecs

  • Author

    Alesanco, A. ; Istepanian, R. ; García, J.

  • Author_Institution
    Commun. Technol. Group, Zaragoza Univ.
  • fYear
    2005
  • fDate
    25-28 Sept. 2005
  • Firstpage
    45
  • Lastpage
    48
  • Abstract
    This paper discusses the error effects in wavelet compression codecs for real-time ECG monitoring in a wireless telecardiology application. Two different strategies for ECG coding are presented and the error effects in the received ECG signals are discussed. Both quantitative (RMS error index) and qualitative (cardiologist opinions) are presented in order to decide if it is useful to monitor retrieved information from ECG packets received with errors or erroneous packets should be discarded. Although RMS index suggests that it would be recommendable to show them, cardiologists conditioned their preference to the number of erroneous blocks in the monitoring process: few number of errors, monitoring no information; high number of errors, monitoring erroneous information
  • Keywords
    codecs; electrocardiography; encoding; error analysis; medical signal processing; patient monitoring; radiocommunication; telemedicine; wavelet transforms; ECG coding; RMS error index; real-time electrocardiography monitoring; transmission errors; wavelet compression codecs; wireless telecardiology; Cardiology; Codecs; Condition monitoring; Electrocardiography; Frequency estimation; Hospitals; Patient monitoring; Telemedicine; Wavelet packets; Wavelet transforms;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computers in Cardiology, 2005
  • Conference_Location
    Lyon
  • Print_ISBN
    0-7803-9337-6
  • Type

    conf

  • DOI
    10.1109/CIC.2005.1588029
  • Filename
    1588029