• DocumentCode
    3183580
  • Title

    Numerical analysis of DUT-size effect on PIM measurement using Standing-Wave Coaxial Tube

  • Author

    Ishibashi, Daijiro ; Kuga, Nobuhiro

  • Author_Institution
    Fac. of Eng., Yokohama Nat. Univ., Yokohama, Japan
  • fYear
    2009
  • fDate
    7-10 Dec. 2009
  • Firstpage
    2609
  • Lastpage
    2612
  • Abstract
    In this paper evaluations of standing-wave coaxial tube method are carried out using modified FDTD method. First, a numerical result on the miss-alignment effect is presented in comparison with an experimental result. It shows that the miss- alignment effect does not affect PIM generated. Next, an influence of the DUT size is examined using a strip conductor. An approach of a conductor to an inner of a coaxial tube influenced upon PIM. Finally, the PIM-source-size effect incorporated into a long size DUT is examined in comparison with an experimental result. It presents the period characteristic of PIM by variation of PIM-source-size.
  • Keywords
    coaxial cables; finite difference time-domain analysis; passive networks; DUT-size effect; PIM measurement; device under-the-test; miss-alignment effect; modified FDTD method; numerical analysis; passive intermediation; passive linear circuit; standing-wave coaxial tube method; strip conductor; Coaxial components; Numerical analysis; FDTD method; Microstrip line; Passive Inter-modulation; Standing-Wave Coaxial Tube Method;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Microwave Conference, 2009. APMC 2009. Asia Pacific
  • Conference_Location
    Singapore
  • Print_ISBN
    978-1-4244-2801-4
  • Electronic_ISBN
    978-1-4244-2802-1
  • Type

    conf

  • DOI
    10.1109/APMC.2009.5385244
  • Filename
    5385244