Abstract
This paper describes the design and construction of the movable RF screening wall of the Combined Mode Chamber (CMC) at DSTO. The CMC provides an RF environment for whole aircraft High Intensity Radiated Field (HIRF) testing using one of the available three modes: Stirred Mode, Transverse Electromagnetic (TEM) and Direct Current Injection (DCI). The movable wall (6 m × 11 m) is an integral part of the CMC since it allows the easy transition between stirred mode and TEM/DCI testing techniques, minimising the need of relocating and reconfiguring the equipment-under-test (EUT) together with maintaining a secure environment for high value assets. Measurement of usable field volume in the Combined Mode Chamber, configured for TEM operation showed that the new screening wall provides the required level of isolation and hence improves the frequency continuity of the chamber.
Keywords
radiofrequency filters; DCI testing techniques; DSTO; EUT; HIRF testing; TEM testing techniques; aircraft high intensity radiated field; combined mode chamber; direct current injection; equipment-under-test; movable RF screening wall construction; movable RF screening wall design; movable wall; stirred mode; transverse electromagnetic; Direct Current Injection; TEM cell; computational electromagnetic modelling; reverberation;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility Symposium - Melbourne (EMC Melbourne), 2010
Conference_Location
Melbourne, VIC
Print_ISBN
978-1-4244-8695-3
Type
conf
DOI
10.1109/EMCSA.2010.6141512
Filename
6141512
Link To Document