DocumentCode :
3187400
Title :
A new snubber circuit for high efficiency and overvoltage limitation in three-level GTO inverters
Author :
Suh, Jae-Hyeong ; Lee, Yo-Han ; Suh, Bum-Seok ; Hyun, Dong-seok
Author_Institution :
Dept. of Electr. Eng., Hanyang Univ., Seoul, South Korea
Volume :
1
fYear :
1995
fDate :
6-10 Nov 1995
Firstpage :
290
Abstract :
A new low loss snubber circuit including overvoltage clamping circuit for a three-level GTO inverter is presented. The proposed snubber circuit is effective in the restriction of the dv/dt and the overvoltage values across each GTO at turn-off and the snubber loss is less than the half that of the conventional RCD snubber circuit. In addition, there is no blocking voltage balancing problem between the inner and the outer GTOs that occurs in the case when a conventional RCD snubber circuit is used in a three-level inverter topology. Experimental results demonstrate that the proposed snubber circuit is very effective for a large capacity three-level GTO inverter
Keywords :
DC-AC power convertors; PWM invertors; losses; protection; snubbers; thyristor convertors; blocking voltage; efficiency; overvoltage limitation; snubber circuit; snubber loss; three-level GTO inverters; topology; turn-off; Circuit topology; Inductors; Pulse width modulation inverters; Snubbers; Stress; Switches; Switching circuits; Switching loss; Transformers; Voltage control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics, Control, and Instrumentation, 1995., Proceedings of the 1995 IEEE IECON 21st International Conference on