DocumentCode :
3188081
Title :
Design and implementation of a calorimetric measurement facility for determining losses in electrical machines
Author :
Szabados, Barna ; Mihalcea, A.
Author_Institution :
Power Res. Lab., McMaster Univ., Hamilton, Ont., Canada
Volume :
3
fYear :
2001
fDate :
2001
Firstpage :
1785
Abstract :
The measurement of the total losses of electrical machines is of most interest to designers for verifying their calculations. These measurements can be done in various ways, however, some lead to more accurate results than others. We will show why the conventional input-output procedure does not result in accurate loss figures, An alternate method is proposed. For this purpose a calorimetric measurement facility was designed and implemented. This paper is intended to present the calibration procedure for this facility, as well as results of tests performed on a 10 hp induction motor
Keywords :
calibration; calorimetry; induction motors; loss measurement; machine testing; 10 hp; calibration procedure; calorimetric measurement facility; electrical machines; induction motor; total losses; Calibration; Dielectrics and electrical insulation; Electric machines; Electric variables measurement; Laboratories; Loss measurement; Manufacturing; Power measurement; Temperature dependence; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference, 2001. IMTC 2001. Proceedings of the 18th IEEE
Conference_Location :
Budapest
ISSN :
1091-5281
Print_ISBN :
0-7803-6646-8
Type :
conf
DOI :
10.1109/IMTC.2001.929507
Filename :
929507
Link To Document :
بازگشت