• DocumentCode
    319270
  • Title

    Novel active filter system composed of inverter bypass circuit for suppression of harmonic resonance at the Yamanashi Maglev test line

  • Author

    Kawaguchi, Ikuo ; Ikeda, Haruo ; Kitano, Jun-ichi ; Ogihara, Yoshiya ; Syogaki, Miyokazu ; Morita, Hiroshi

  • Author_Institution
    Railway Tech. Res. Inst., Kokubunji, Japan
  • Volume
    1
  • fYear
    1997
  • fDate
    3-6 Aug 1997
  • Firstpage
    175
  • Abstract
    The authors have developed and proposed a novel active filter system composed of an inverter bypass circuit for the suppression of harmonic resonance conditions caused between the inductance behind the load bus and the capacitance of VAr equipment, especially at lower harmonic frequencies. They have installed this new harmonic compensation system in combination with TCR-type SVC and shunt LC filters at the Yamanashi Maglev test line. Here, they describe the outline of the reactive power and harmonic compensation systems, and harmonic resonance test results which show satisfactory performance of the active filter
  • Keywords
    DC-AC power convertors; active filters; circuit resonance; harmonic distortion; invertors; magnetic levitation; power filters; power system harmonics; railways; static VAr compensators; thyristor convertors; SVC; VAr equipment capacitance; Yamanashi Maglev test line; active power filter system; filtering performance; harmonic compensation; harmonic resonance suppression; inverter bypass circuit; load bus inductance; reactive power compensation; shunt LC filters; Active filters; Capacitance; Inductance; Inverters; Power harmonic filters; Power system harmonics; RLC circuits; Reactive power; Resonance; System testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Conversion Conference - Nagaoka 1997., Proceedings of the
  • Conference_Location
    Nagaoka
  • Print_ISBN
    0-7803-3823-5
  • Type

    conf

  • DOI
    10.1109/PCCON.1997.645607
  • Filename
    645607